Acoustic Fabric ABSORBER LIGHT

Item No. 1a542*
  • Curtains made from acoustic fabric ABSORBER LIGHT.<br>Clark Music Center Lawrenceville School, NJ / USA

It has traditionally been difficult to to achieve good quality acoustics in a naturally lit environment. 

This situation has led to the development of ABSORBER LIGHT, a translucent yet highly absorbent fabric. It uses micro perforations within the weave to absorb sound. In order to achieve the maximum effect it is advisable to create a distance of 10 - 30 cm between any reverberant surface (e.g a glass window) and the fabric.

Spaces such as offices often require enhanced acoustics while at the same time retaining a light and airy feel. ABSORBER LIGHT can provide the solution.
 

More info

* Required Fields

Item No.: 1a542*
Material: polyester FR
Weight approx.: 149,00 g/m²
Width approx.: 300,00 cm
Piece length approx.: 30,00 m
Flame retardant: EN 13501-1 B-s1,d0, NFPA 701
m

It has traditionally been difficult to to achieve good quality acoustics in a naturally lit environment. 

This situation has led to the development of ABSORBER LIGHT, a translucent yet highly absorbent fabric. It uses micro perforations within the weave to absorb sound. In order to achieve the maximum effect it is advisable to create a distance of 10 - 30 cm between any reverberant surface (e.g a glass window) and the fabric.

Spaces such as offices often require enhanced acoustics while at the same time retaining a light and airy feel. ABSORBER LIGHT can provide the solution.
 

  • 100 % polyester FR (52,23 % PES FR recycled, 34,49 % PES FR , 13,28 % CS)
  • Acoustic certificate available
  • Other colours available upon request. Minimum order of 120 rm (131.2 yds)

Acoustic absorption as measured in reverberation chamber

Evenly hung flat panel with no fullness.
  • Mode of installation: G-150 according DIN EN ISO 354
  • Distance from wall: 150 mm

Acoustic absorption value: αw = 0.55
Acoustic absorption class: D

 

Evenly hung panel with 100% fullness.

  • Mode of installation: G-150 according DIN EN ISO 354
  • Distance from wall: 150 mm

Acoustic absorption value: αw = 0.80
Acoustic absorption class: B